Free · No signup · Formula shown with every result

General Calculators

General-purpose engineering calculators and guides that apply across Electrical, HVAC, Plumbing and Fire systems.

2Live calculators
100%Free, no signup
PDFOne-click download

All General Calculators

Standard-based tools with a PDF result. Free to use, no signup.

2
General

📏 AWG to mm² and mm² to AWG Wire Gauge Converter

Convert AWG to mm² and mm² to AWG, with wire diameter, kcmil, nearest metric size and resistance, and download a PDF result.

Open calculator
General

🧰 MEP Unit Converter

Convert pressure, flow, power, TR, BTU, kW, CFM, gpm, head, energy, temperature and other MEP units quickly and accurately.

Open calculator
No match. Try a different word.

About General Calculators

Not every calculation fits one engineering discipline. Engineers, students and site teams often need to convert a wire size, compare a loan, change units or make a quick estimate. The general calculators on this page cover these everyday tasks in one place, with the formula shown so you can follow every step.

The tools include conversions between wire gauge and cross-section, loan instalment estimates and other planning helpers. Where the answer depends on a standard table or a rounding rule, the page tells you which one was used.

As with every calculator on this site, treat the output as an estimate. Wire sizes, financial products and units can differ between standards and between lenders, so check the final figures against the documents that apply to you.

Every calculator explains the formula behind the result and lists common mistakes, so you can verify the answer instead of trusting a black box. Results are for estimation and learning, so always confirm final designs against the applicable code and with a qualified engineer.

How General calculations fit together

The result of one step usually becomes the input of the next. This is a practical order to follow when you check a design.

  1. Pick the right tool. Choose the calculator that matches the quantity you need, and read the short description on its page.
  2. Check the units. Confirm whether the tool expects millimetres, square millimetres, years or months before you enter a value.
  3. Enter your own values. Fill every field with the numbers from your project or your offer letter.
  4. Read the formula. Compare the formula shown with the one you expect, especially if another source gives a different answer.
  5. Round sensibly. For wire and loans, round to the nearest standard size or the nearest whole currency unit as the case requires.

Worked General examples you can verify by hand

These short examples show the arithmetic behind the tools. The numbers are illustrative, so replace them with your own project values.

AWG to cross-section in mm²

AWG 10 has a diameter of about 2.588 mm, found from the standard formula d = 0.127 × 92^((36 − n) ÷ 39) mm.

Area = π ÷ 4 × d²= 0.7854 × 2.588²

≈ 5.26 mm² cross-section

Monthly instalment of a loan

A loan of ₹5,00,000 at 9% a year for 60 months. The monthly rate is r = 0.09 ÷ 12 = 0.0075.

EMI = P × r × (1 + r)ⁿ ÷ ((1 + r)ⁿ − 1)= 500,000 × 0.0075 × 1.5657 ÷ 0.5657

≈ ₹10,379 a month, about ₹1,22,750 of interest over the term

Motor rating: kW to HP

One mechanical horsepower is about 0.7457 kW. A motor is rated at 7.5 kW.

HP = 7.5 ÷ 0.7457

≈ 10.06 HP

Common mistakes to avoid

Most calculation errors come from small habits, not from hard formulas.

  • Thinking a bigger AWG number means a thicker wire.It is the opposite: a smaller AWG number is a thicker wire.
  • Entering the tenure in the wrong unit.An EMI calculation uses months. Years must be multiplied by 12.
  • Forgetting extra loan costs.Processing fees, insurance and prepayment charges are not in a basic EMI formula.
  • Mixing types of horsepower.Mechanical, metric and electrical horsepower differ slightly, so check which one is meant.
  • Treating a converted size as exact.A calculated area rarely matches a standard cable size exactly, so choose the nearest standard size.

General terms in plain words

Short definitions of the terms you will meet in these calculators.

AWG
American Wire Gauge, a standard that gives wire sizes by number.
mm²
Square millimetre, the cross-sectional area of a conductor.
EMI
Equated monthly instalment, the fixed amount paid each month on a loan.
Principal
The amount borrowed before any interest.
Tenure
The length of time over which a loan is repaid.
HP and kW
Two units of power. One mechanical HP is about 0.7457 kW.
Estimation
A quick approximate calculation that helps you plan before final design.

Frequently asked questions

Quick answers about the General calculators.

Are the General calculators free?

Yes. All calculators on this page are free to use and do not need a signup or login.

Do the calculators show the formula?

Yes. Each calculator explains the formula behind the result, with a worked example and a list of common mistakes.

Why does a smaller AWG number mean a thicker wire?

The gauge number comes from the number of drawing steps used to make the wire. More steps make it thinner, so a higher number is a thinner wire.

Can a cross-section in mm² be converted exactly to AWG?

Not usually. The calculation gives a size between two standard gauges, so pick the nearest standard size and check the current rating.

How is an EMI calculated?

From the loan amount, the monthly interest rate and the number of months, using the formula shown on the EMI calculator page.

Does the EMI result include fees?

No. It covers the principal and the interest only, so ask your lender about other charges.

Are these calculators suitable for final design?

They are for estimation and learning. Check final figures against the relevant standard or document.

Looking for another calculator?

Browse every MEP calculator in one place, enter your values and get a clear, explained result.

⚡ View all calculators
Scroll to Top