How to Calculate Pump Head and Pump Power: TDH, kW and HP Explained

When people choose a water pump, they often look only at the height of the tank and pick a motor to match. That shortcut ignores the energy lost to friction in the pipes, and it ignores the pressure needed at the outlet. The result is a pump that delivers less water than expected, or a motor that runs hot. This guide explains total dynamic head (TDH) in plain words, shows how to turn it into pump power in kW and HP, and works through two examples you can repeat by hand.

The short answer: the pump must lift the water to its destination and overcome friction in the pipes and supply any pressure needed at the outlet. Add these three together and you have the total dynamic head (TDH). Then hydraulic power (kW) = 9.81 × flow (m³/s) × TDH (m), and the motor must supply that power divided by the pump efficiency, plus a margin.

What “head” means

Head is a way to express pressure as the height of a water column. A pump that can push water up 30 m is said to have 30 m of head. Using metres of head instead of pressure makes the arithmetic simple, because lifting, friction and pressure can all be added in the same unit.

Pressure unit Equivalent head of water
1 bar about 10.2 m
1 kg/cm² about 10 m
1 psi about 0.703 m
1 kPa about 0.102 m

The parts of total dynamic head

TDH = static head + friction head + residual (outlet) head
Part What it is How to find it
Static head The vertical height from the water surface at the source to the water outlet at the destination. Measure the levels. It does not depend on flow.
Friction head Energy lost as water rubs against the pipe walls and passes through bends, valves and fittings. Calculate from flow, pipe size, pipe length and pipe roughness. It rises quickly as flow rises.
Residual head The pressure still needed at the outlet, for example at a tap, shower or sprinkler. Take the required pressure from the fixture data and convert it to metres.

A tank that fills from the top has almost no residual head, because the water simply flows out into an open tank. A pressure booster supplying showers has a large residual head, because the water must arrive with pressure. A small velocity head term also exists, but in ordinary building pipework it is usually small enough to ignore for a first estimate.

Step 1: Decide the flow rate

Flow (Q) is the volume you need to move divided by the time you have to move it.

Q (m³/h) = volume to move (m³) ÷ pumping time (hours)

For a residential building, start from the daily water demand, then decide how many hours per day the pump may run. The Daily Water Demand Calculator helps with the first number. To use the flow in the power formula, convert it to m³/s by dividing m³/h by 3600.

Step 2: Choose the pipe size

The pipe size decides how much head is lost to friction. A smaller pipe makes the water move faster, and friction rises very quickly with speed. Many designers keep the velocity in the delivery pipe roughly between 1.5 and 2.5 m/s, and lower on the suction side, but the correct limits depend on your project specification. You can check your choice with the Pipe Sizing Calculator.

Velocity (m/s) = Q (m³/s) ÷ pipe cross-section area (m²)
Area = π × d² ÷ 4, with d in metres

Step 3: Calculate the friction head

A widely used formula for water in pipes is the Hazen-Williams equation. In SI units it is:

hf = 10.67 × L × Q^1.852 ÷ (C^1.852 × d^4.87)

Here hf is the friction head in metres, L is the pipe length in metres, Q is the flow in m³/s, d is the internal pipe diameter in metres, and C is a roughness coefficient. C is higher for smooth pipes. Commonly used values run from about 150 for new plastic pipe down to about 100 for old, rough metal pipe. For fittings, many designers add an allowance of roughly 10% to 30% on top of the straight-pipe friction. Use the allowance your project specification calls for.

Step 4: Add everything to get TDH

Add the static head, the friction head (suction and delivery together) and the residual head. This TDH, together with the flow, is the duty point you give to the pump supplier.

Step 5: Convert TDH and flow into power

Hydraulic power (kW) = 9.81 × Q (m³/s) × TDH (m)
Pump shaft power (kW) = hydraulic power ÷ pump efficiency
Motor input power (kW) = shaft power ÷ motor efficiency
1 HP = 0.746 kW

The hydraulic power is the power that actually reaches the water. The pump is not perfectly efficient, so the shaft must supply more. Small pumps are often in the range of about 40% to 65% efficient, but the real figure comes from the pump curve or the data sheet. Finally, choose a motor with a margin above the shaft power. The size of the margin depends on the pump type and the specification, and values around 10% to 20% are commonly used. Select the next standard motor rating above the result.

Worked example 1: pumping from a sump to an overhead tank

A building’s underground sump must be pumped to an overhead tank. All values below are illustrative numbers for learning, so replace them with your own site data.

Given data Value
Water to be moved 27 m³ per day, pumped in about 2.25 hours
Static head 26 m (sump water surface to the tank inlet)
Pipe 50 mm internal diameter, new plastic, C = 140
Total pipe length 60 m (suction and delivery together)
Fittings allowance 20% of the pipe friction
Residual head 0 m (water enters an open tank)
Assumed pump efficiency 55%

Flow and velocity

Q = 27 ÷ 2.25 = 12 m³/h = 12 ÷ 3600 = 0.003333 m³/s
Area = π × 0.05² ÷ 4 = 0.001963 m²
Velocity = 0.003333 ÷ 0.001963 ≈ 1.70 m/s

A velocity of about 1.7 m/s is reasonable for a delivery pipe.

Friction head

hf = 10.67 × 60 × (0.003333)^1.852 ÷ (140^1.852 × 0.05^4.87)
hf ≈ 3.8 m
With 20% for fittings = 3.8 × 1.2 ≈ 4.6 m

Total dynamic head

TDH = 26 + 4.6 + 0 = 30.6 m

Power

Hydraulic power = 9.81 × 0.003333 × 30.6 ≈ 1.00 kW
Shaft power = 1.00 ÷ 0.55 ≈ 1.82 kW
With a 15% margin = 1.82 × 1.15 ≈ 2.09 kW
Result: the duty point is about 12 m³/h at 30.6 m head, and the next standard motor above 2.09 kW is 2.2 kW (about 3 HP). If the motor efficiency is 85%, its electrical input at the shaft load of 1.82 kW is about 1.82 ÷ 0.85 ≈ 2.14 kW, which is the figure to use when sizing the supply cable.

You can compare your own numbers with the Pump Head (TDH) and Pump Power Calculator.

Worked example 2: what a smaller pipe does

Keep everything in example 1 the same, but now use a 40 mm internal diameter pipe to save on pipe cost.

Area = π × 0.04² ÷ 4 = 0.001257 m²
Velocity = 0.003333 ÷ 0.001257 ≈ 2.65 m/s
hf = 10.67 × 60 × (0.003333)^1.852 ÷ (140^1.852 × 0.04^4.87) ≈ 11.3 m
With 20% for fittings = 11.3 × 1.2 ≈ 13.5 m
TDH = 26 + 13.5 = 39.5 m
Hydraulic power = 9.81 × 0.003333 × 39.5 ≈ 1.29 kW
Shaft power = 1.29 ÷ 0.55 ≈ 2.35 kW
With a 15% margin = 2.35 × 1.15 ≈ 2.70 kW
Pipe Velocity Friction (with fittings) TDH Shaft power
50 mm 1.70 m/s 4.6 m 30.6 m 1.82 kW
40 mm 2.65 m/s 13.5 m 39.5 m 2.35 kW
Result: reducing the pipe from 50 mm to 40 mm cut the pipe diameter by only 20%, yet friction head nearly tripled. The pump now needs about 29% more shaft power, and with the margin the motor moves up to the next standard size above 2.2 kW. The velocity of 2.65 m/s is also above the range mentioned earlier. The saving on pipe cost is quickly lost in a larger pump and higher electricity use every year.

Suction side: do not forget it

A surface pump pulls water in by lowering the pressure at its inlet, so it cannot lift water without limit. Atmospheric pressure at sea level can support a water column of about 10.3 m in theory, and real pumps manage much less once friction, temperature and the pump’s own requirements are taken into account. Keep the suction pipe short, straight and at least as large as the pump inlet, and check the pump’s required suction condition (NPSH) in the manufacturer’s data. For deep wells, a submersible pump is used instead of a surface pump.

Common mistakes

  • Using only the tank height as the head and ignoring friction and outlet pressure.
  • Ignoring the suction side of the pipework when adding up friction.
  • Mixing hydraulic power and shaft power. The motor must supply the shaft power, which is larger.
  • Mixing pressure units. Convert bar, kg/cm² or psi to metres of head before adding them.
  • Choosing a small pipe to save cost and paying for it later in a larger pump and higher energy use.
  • Running a pump far from its duty point on the curve, which wastes energy and can wear the pump.
  • Forgetting the motor’s electrical load when sizing the cable and breaker.

Quick checklist

  • Flow rate decided from volume and pumping time
  • Pipe size chosen and velocity checked
  • Friction head calculated, including fittings
  • Static head and residual head added to get TDH
  • Hydraulic power, shaft power and motor size calculated with a margin
  • Suction conditions checked against the pump data
  • Electrical supply sized for the motor

Frequently asked questions

What is TDH in a pump?

TDH, or total dynamic head, is the total height of water the pump must overcome. It is the sum of the static lift, the friction losses in the pipes and fittings, and the pressure needed at the outlet.

How do I convert kW to HP for a pump motor?

Divide the kW by 0.746. For example, 2.2 kW is about 2.95 HP, which is sold as a 3 HP motor.

Why does the pump need more power than the hydraulic power?

The pump loses energy inside itself to friction and leakage, so only a share of the shaft power reaches the water. That share is the pump efficiency.

Does a bigger pipe reduce the pump size?

Yes, often. A larger pipe lowers the friction head, so the TDH and the power both fall. The cost of the larger pipe has to be weighed against the saving on the pump and the energy.

Can I use pressure in bar instead of head?

You can, as long as you stay consistent. Convert bar to metres of head (1 bar is about 10.2 m) before adding it to the static and friction head.

Is a calculator enough to select a pump?

A calculator gives a good first estimate of the duty point and the motor size. The final pump selection should be made from the manufacturer’s pump curve, together with the applicable code and a qualified engineer.

Note: This guide is for learning and estimation. The efficiency, roughness and margin values in the examples are illustrative. Always verify the final design against the applicable standards, the pump manufacturer’s curves and a qualified engineer. See the full Disclaimer.
A note from MEP Analysis: Before you calculate anything, draw a simple sketch of the water path and write the levels, pipe sizes and lengths on it. Most pump sizing errors come from a missing length or a wrong level, not from the formulas, and a one-minute sketch catches them early.

Try it yourself

Enter your own flow, pipe size, length and levels in the calculator and compare the result with the hand calculations above. Once you know the motor size, the next step is to choose a supply cable for it, which is covered in our cable size selection guide.

💧 Open the Pump Head and Power Calculator

Related tools:
Pipe Sizing Calculator ·
Daily Water Demand Calculator ·
Borewell Pump HP Calculator ·
STP Size Calculator

Scroll to Top